Loading...
Indoor Power Conversion System

Indoor Power Conversion System

Power Conversion System
Short Description

AEME’s Indoor Power Conversion System (PCS), designed for Energy Storage Systems (ESS), delivers high efficiency, safety, and rapid response with millisecond charge-discharge response. It supports multi-system parallel operation and multiple communication protocols. It features intelligent air cooling for -30°C to 60°C environments with no derating at 45°C. Rich communication interfaces like Ethernet, RS485, and CAN ensure seamless integration.

 

Product Description

Feature And Application of Indoor Power Conversion System

  • High Efficiency
    Three-level topology with a maximum efficiency exceeding 99%.

  • Quick Response
    Fast dynamic response with millisecond-level charge-discharge conversion time.

  • Easy Expansion
    The power conversion system supports multi-machine parallel operation for scalable deployment.

  • Multiple Communication Protocols&Interfaces  
    Compatible with IEC61850, IEC104, Modbus, CAN, and other protocols. Equipped with Ethernet, RS485, CAN, and other communication ports.

  • High Altitude Operation
    Operates reliably at altitudes up to 4000 meters.

  • Intelligent Air Cooling
    Suitable for ambient temperatures from -30°C to 60°C, with no derating at 45°C.

 

Specification of Indoor Power Conversion System

Product Model ESS-PCS-1250 ESS-PCS-1725
Rated Power (kW) 1250 1725
Maximum Apparent Power (kVA) 1375 1897
DC Side
Maximum DC Voltage (V) 1500
Maximum DC Current (A) 1403 1936
Battery Voltage Range (V) 1000~1500
Grid-Connected AC Side
Rated Grid Voltage (V) 690, 3W+PE
Grid Voltage Range 690 VAC-15% ~ +10%
Maximum AC Output Current (A) 1151 1588
Rated Grid Frequency (Hz) 50
THDi (at rated power) <3% (Ipn)
Power Factor Adjustment Range -1 (leading) ~ 1 (lagging)
Off-Grid AC Side Parameters
Rated Off-grid Voltage (V) 630, 3W+PE
Rated Frequency (Hz) 50
Voltage Total Harmonic Distortion < 3% (linear load)
Environmental Conditions
Operating Temperature (°C) -35~60 (derating above 45°C)
Operating Humidity ≤95% (non-condensing)
Operating Altitude (m) ≤4000 (derating above 2000m)
System Data
Isolation Method Transformerless
Maximum Efficiency 99%
Ingress Protection Rating IP20
Cooling Method Intelligent Air Cooling
Communication Interfaces RS485 / CAN / Ethernet
Communication Protocols Modbus-RTU /  Modbus-TCP / IEC61850 / IEC104
Noise (dB) <80
System Dimensions (W×H×D, mm) 1400 × 2000 × 800
Weight (kg) <1500